Part of Knauf

Load-bearing Capacity

Load bearing under extreme conditions


The load capacity of the ceiling systems is tested in accordance with the principles set by the EN 13964 standard, 2004. The load capacity is expressed as a combination of the deflection classes, the humidity classes, the net weight and the built-in weight.

Under extreme conditions of 90% RH and 30° and the allowed deflection of max. L/300 mm, the tensile strength and the load bearing capacity of Knauf Danoline products is as follows:

Load Products Formats Perforation
 170 N Corridor F30 300xmax.2800 G, Q, M, R
 30 N Danotile White & Metallic 600x600x9.5; 625x625x9.5 R
Designpanel 1200x2400x12.5  G2F, Q2F, M2F, R
Tectopanel 600x2400x12.5 G, Q, M, R
Contrapanel 600x1200/1800/2400x12.5 G1F, R 
 No Load Markant 600x1200x12.5; 625x1250x12.5; 500x500x9.5  G, Q, M, R 
Belgravia 600x1200x12.5; 625x1250x12.5 G, Q, M, R 
Plaza 600x1200x9.5; 625x1250x9.5   G, Q, M, R 
Medley 600x600x9.5  R
Danotile White & Metallic 600x600x9.5; 625x625x9.5 R
Corridor 400 400x2400x9.5  G, Q, M, R 
Tectopanel 600x2400x12.5 T
Danopanel 600x600x12.5   G, Q, M, R