Part of Knauf

Load-bearing Capacity

Load bearing under normal conditions


The load capacity of the ceiling systems is tested in accordance with the principles set by the EN 13964 standard, 2004. The load capacity is expressed as a combination of the deflection classes, the humidity classes, the net weight and the built-in weight.

Under normal conditions of 70% RH and 25° and the allowed deflection of max. L/300 mm, the tensile strength and the load bearing capacity of Danoline products is as follows:

Load Products Formats Perforation
30 N Markant 600x600x12.5; 625x625x12.5; 500x500x9.5 G, Q, M, R
Belgravia 600x600x12.5; 625x625x12.5 G, Q, M, R
Plaza 600 600x600x9.5; 625x625x9.5 G, Q, M, R
Medley 600x600x9.5 R
Corridor 400 400x2400x12.5 G, Q, M, T, R
     
No Load Unity 6 System 600x600x12.5 U6
Contur 600x600x12.5; 625x625x12.5 G, Q, M, T, R
Vista 400x1200x12.5 T
Linear 600x600x12.5 G, Q, M, R
Markant 600x1200x12.5; 625x1250x12.5 G1F, Q1F, M1F, R
Markant 600x600x12.5; 625x625x12.5 T
Belgravia 600x1200x12.5; 625x1250x12.5 G1F, Q1F, M1F, R
Belgravia 600x600x12.5; 625x625x12.5 T
Plaza 600x1200x9.5; 625x1250x9.5 G1F, Q1F, M1F, R
Plaza 600x600x12.5; 625x625x12.5 T
Danotile White & Metallic 600x1200x6.5 R
Corridor Swing 600xmax.1800x12.5 G, Q, M, R
Designpanel 900x2700x12.5 G1F, Q1F, M1F, T3L1, T3L3, R
Designpanel 1200x2400x12.5 T4L4
Danopanel 600x600x12.5 G, Q, M, R