Read more What is the minimum installation depth for suspended ceilings?
The minimum installation depth depends on the product. The specific guidelines for each product can be found in the installation guides. Choose the desired product from the product overview or use the Product Selector to search for a product meeting your requirements.
Read more What is the maximum weight of the installations built directly into the ceiling tile?
The maximum weights of the installations built directly into the ceiling tile are specified under “Load-bearing capacity”.
Read more What is the difference between a wall angle and a shadow edge trim?
In general, the difference between a wall angle and a shadow trim line lies in the aesthetical effect. The wall angle acts like a frame around the ceiling, whereas a shadow trim line a floating effect.
For Corridor 400, the difference in also in the installation depth. A wall angle requires an installation depth of 300mm whereas with a shadow trim line the ceiling can be mounted with a 100mm cavity.
Read more What type of furring can be used for installation of Designpanel?
Designpanel can be mounted on either steel, i.e. CD profiles, or on wooden furring, e.g. 45x45mm or 22x95mm battens.
Read more Can Designpanel be mounted directly onto a hard surface (e.g. 13mm gypsum boards)?
No.
For optimal acoustic effect, Designpanel must be mounted on 45mm furring with mineral wool backing.
 
Read more Where should the steam blocking be placed?
The steam blocking must not be placed directly on to the perforated gypsum board. For acoustic reasons and in order to prevent partial vacuum, the steam blocking is to be placed min. 10mm away from the perforated gypsum board.
Read more How many perforated gypsum boards are necessary in a room?
In private houses, the amount of perforated gypsum board necessary can be calculated by means of the formula: Volume (m³) x 0.18 = m² of perforated gypsum boards. Learn more about use of Danoline products in private houses under DIY.
In other building types, the amount of acoustic materials is calculated based on the required reverberation time. The calculation is provided by Danoline’s Customer Service Centre.
Read more What is the consumption of screws for mounting of Contrapanel?
Consumption varies according to panel size.

NON-DEMOUNTABLE CEILING WALL LINING
Per panel:
600x1200 mm = 16 screws
600x1800 mm = 22 screws
600x2400 mm = 28 screws
Per panel:
600x1200 mm = 20 screws
600x1800 mm = 28 screws
600x2400 mm = 36 screws
Per m²:
600x1200 mm = 22.2 screws/m²
600x1800 mm = 20,4 screws/m²
600x2400 mm = 19,5 screws/m²
Per m²:
600x1200 mm = 27.8 screws/m²
600x1800 mm = 26 screws/m²
600x2400 mm = 25 screws/m²

Learn more about Contrapanel
Read more What is the consumption of joint filling for Solopanel or Stratopanel?
The consumption of the joint filling materials is as follows: 
        Uniflott – 0.4 kg/m²
        Finish Pastös – 0.05-0.1 kg/m²
        Primer – 0.02 l/m²
 